Sumitomo F50 Compressor Manual New -

The gas is pressurized within the compressor capsule, generating heat.

The unit should never be tilted more than 30° during transport or operation. sumitomo f50 compressor manual new

The manual strictly warns not to use an inverter as the main power source. Operating Principles The gas is pressurized within the compressor capsule,

Low-pressure helium returns from the cold head through a return connector. sumitomo f50 compressor manual new

The F-50 comes in two primary variants: the (low voltage) and the F-50H (high voltage). Specification Cooling Method Water-cooled Electrical Supply (F-50L) 3 Phase 200 V, 50/60 Hz Electrical Supply (F-50H) 3 Phase 380-415 V (50 Hz) / 460-480 V (60 Hz) Power Consumption 6.5–7.2 kW (50 Hz) / 7.5–8.3 kW (60 Hz) Helium Pressure (Static) ~1.60–1.65 MPa at 20°C (varies by model) Helium Pressure (Operating) High side: 1.90–2.20 MPa; Low side: 0.40–0.60 MPa Dimensions (HxWxD) 591 x 450 x 585 mm (23.3 x 17.7 x 19.1 in) Weight ~120 kg (264 lbs) Installation & Environmental Requirements